Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
PeerJ ; 11: e14764, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36743962

RESUMO

In combat sports, strikes or counter-strikes response time (RT) can be related to performance and sporting success. Moreover, training sessions are usually highly fatiguing, which is expected to impair basic skills, such as RT. Thus, this study aimed to investigate the effect of fatigue on punch and kick RTs of karate practitioners. Twelve individuals of both sexes from different levels (three yellow belts, three red belts, two orange belts, two green belts, one brown belt, and one black belt) were selected. Participants were aged 22 ± 3 years old, with a stature of 169.1 ± 6.5 cm, and a body mass of 65.5 ± 10 kg. Six visits were held with each participant. On the first 2 days, the RT of punches and kicks was measured by a validated smartphone app (TReaction). For the subsequent visits, a randomized incremental test for the upper or lower body was adopted as motor fatigue protocol, immediately followed by punches and kicks RT tests, also in random order. For induction of lower and upper body-specific muscle fatigue, the ITStriker app was used, which operates by emitting sound signals transmitted by a smartphone. One-way repeated measures ANOVA was performed, and significance was set at p ≤ 0.05. Regarding the mean punches RT, significant effects between situations for the upper (F(2,22) = 11.5; ω2 = 0.23; p < 0.001) and lower body (F(2,22) = 14.2; ω2 = 0.18; p < 0.001) fatigue protocols were found. The negative effect of the lower body fatigue protocol in punches RT was evident regardless of the order of the tests (punch RT first: Δ = 10.5%; t = 4.4; p < 0.001; d = 1.0; kick RT first: Δ = 11.4%; t = 4.8; p < 0.001; d = 1.1). Regarding mean kicks RT, significant effects were found between situations for the lower (F(2,22) = 16.6; ω2 = 0.27; p < 0.001) but not for the upper (F(2,22) = 2.3; ω2 = 0.02; p = 0.12) body fatigue protocols. Kick RTs were negatively affected by the lower body fatigue protocol regardless of the RT order applied (punch RT first: Δ = 7.5%; t = 3.0; p = 0.01; d = 0.8; kick RT first: Δ = 14.3%; t = 5.7; p < 0.001; d = 1.5). Upper body fatigue does not impair punch or kick RTs. Thus, it is concluded that the specificity of fatigue protocols and striking order should be considered while performing RT demanding techniques in karate practice. Specifically, lower body motor fatigue may impair both kicks and punches RT, which highlights the role of lower limbs in punches performance. Otherwise, upper body motor fatigue seems to induce impairments that are limited to the specific motor actions of this body segment.


Assuntos
Artes Marciais , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Atletas , Extremidade Inferior/fisiologia , Artes Marciais/fisiologia , Fadiga Muscular , Tempo de Reação
2.
Rev. Ciênc. Méd. Biol. (Impr.) ; 20(2): 327-332, set 29, 2021. fig
Artigo em Inglês | LILACS | ID: biblio-1354629

RESUMO

Introduction: curved and hooked acromia play a key role in shoulder impingement syndrome. Little is known about acromial type in the Brazilian population. Aim: To describe the acromial profile of Brazilian young adults; to evaluate its correlation with gender and handedness and the occurrence of symmetry between the genders. Methodology: forty acromia in 20 Brazilian adults of both genders, aged 21-25 years, were studied. The acromial type was classified through the Bigliani/Epstein method using radiographs in supraspinatus outlet view. Results: as there was no gender difference in occurrences of acromial type, we considered the male and female groups together. Thus, among the 20 right acromia, we found 5 type I (25%), 8 type II (40%) and 7 type III (35%). Among the 20 left acromia, we found 4 type I (20%), 11 type II (55%) and 5 type III (25%). The only left-handed volunteer (100%) presented acromial type III in both the right and the left shoulder. Among the 19 right-handed volunteers, 5 (26.3%) presented right acromion type I, 8 (42.1%) had type II and 6 (31.6%) had type III; for the left acromion, 4 (21.1%) presented type I, 11 (57.9%) had type II and 4 (21.1%) had type III. Acromial symmetry occurred in 60% of females and 70% of males. Conclusion: type II acromion was predominant, in both the right and the left shoulder in Brazilian young adults. There was no correlation between acromial type and gender. It was not possible to analyze the correlation between acromial type and handedness. Acromial type tended to be symmetrical in our sample.


Introdução: o acrômio curvo e gancho desempenham um papel fundamental na Síndrome do impacto do ombro. Pouco se sabe sobre o tipo acromial na população brasileira. Objetivo: descrever o perfil do tipo acromial em adultos jovens brasileiros e avaliar sua correlação com o gênero e a lateralidade e a ocorrência de simetria entre os sexos. Metodologia: foram estudados 40 acrômios de 20 adultos brasileiros, de ambos os sexos, com idade entre 21 e 25 anos. O tipo acromial foi classificado pelo método de Bigliani/ Epstein nas radiografias de perfil de escápula. Resultados: como não houve diferença na ocorrência do tipo acromial quanto ao gênero, consideramos os grupos masculino e feminino juntos. Assim, dos 20 acrômios direitos, foram encontrados 5 (25%) do tipo I, 8 (40%) do tipo II e 7 (35%) do tipo III, enquanto que dos 20 acrômios esquerdos, foram encontrados 4 (20%) tipo I, 11 (55%) tipo II e 5 (25%) tipo III. O único voluntário canhoto (100%) apresentou para o ombro direito e esquerdo o tipo acromial III. Dos 19 voluntários destros, 5 (26,3%) apresentavam acrômio direito tipo I, 8 (42,1%) tipo II e 6 (31,6%) tipo III; para o acrômio esquerdo, 4 (21,1%) apresentavam tipo I, 11 (57,9%) tipo II e 4 (21,1%) tipo III. A simetria acromial ocorreu nos grupos feminino (60%) e masculino (70%). Conclusão: o acrômio tipo II foi o mais predominante para os ombros direito e esquerdo em adultos jovens brasileiros. Não houve correlação entre o tipo de acromial e o gênero. Não foi possível analisar a correlação entre o tipo acromial e a lateralidade. O tipo acromial tende a ser simétrico em na amostra estudada.


Assuntos
Humanos , Masculino , Feminino , Adulto , Escápula , Ombro , Síndrome de Colisão do Ombro , Dor de Ombro , Lesões do Manguito Rotador , Identidade de Gênero , Lateralidade Funcional
3.
Rev. Ciênc. Méd. Biol. (Impr.) ; 20(1): 33-39, maio 5, 2021. fig, tab
Artigo em Português | LILACS | ID: biblio-1354793

RESUMO

Introdução: em 1875, Hamilton identificou o formato do acrômio como uma etiologia de dor no ombro. Neer, em 1972, descreveu a síndrome do impacto no ombro como uma relação de causa e efeito entre a morfologia do acrômio e o impacto subacromial. Em 1986, Bigliani et al. apresentaram um esquema de classificação do acrômio de acordo com o formato de sua superfície inferior: plano (tipo I), curvo (tipo II) e gancho (tipo III). Em 1993, Epstein et al. proporam que o acrômio tipo II apresentaria um declive em seu terço médio e o tipo III no seu terço anterior. Objetivo: avaliar a reprodutibilidade/confiabilidade interavaliador do método de Bigliani et al. (1986) refinado por Espstein et al. (1993) para a classificação do tipo acromial. Metodologia: casuística composta por 20 voluntários brasileiros, de ambos os gêneros, entre 21-25 anos. A incidência radiográfica utilizada para visualizar o formato do acrômio foi perfil de escápula. O tipo acromial foi classificado por três avaliadores. A reprodutibilidade e confiabilidade foram avaliadas pelo teste McNemar e pelo índice Kappa. Resultados: teste de McNemar com p > 0,05; índice Kappa entre 0,61 e 0,8; e probabilidade de significância p de Kappa < 0,05 confirmam a muito boa reprodutibilidade e confiabilidade do método para classificação do tipo acromial entre os três avaliadores. Conclusão: o método de Bigliani et al. (1986) refinado por Epstein et al. (1993) para classificação do tipo acromial mostrou concordância entre todos os avaliadores confirmando a muito boa reprodutibilidade e confiabilidade entre os avaliadores do estudo.


Introduction: in 1875, Hamilton identified that acromion shape was an etiology for shoulder pain. In 1972, Neer described shoulder impact syndrome as a cause and effect relationship between acromion morphology and subacromial impact. In 1986, Bigliani et al. presented an acromion classification scheme according to the shape of its lower surface: flat (type I), curved (type II) and hook (type III). In 1993, Epstein et al. proposed that the type II acromion would have a slope in its middle third and type III in its anterior third. Objective: to evaluate the inter-rater reproducibility and reliability of the method of Bigliani et al. (1986) for classifying acromial type, as refined by Epstein et al. (1993). Methodology: this was a case series composed of 20 Brazilian volunteers of both genders, aged 21-25 years. The shape of the acromion was visualized radiographically using the supraspinatus outlet view. Acromial type was classified by three evaluators. Reproducibility and reliability were assessed using the McNemar test and kappa index. Results: the McNemar test showed probability p > 0.05 and the kappa index was between 0.61 and 0.8 significant result: p < 0.05. These confirmed that this method had very good reproducibility and reliability for classifying acromial type among the three evaluators. Conclusion: the method of Bigliani et al. (1986) for classifying acromial type, as refined by Epstein et al. (1993) showed agreement among all the evaluators. This confirmed that there was very good reproducibility and reliability among the evaluators of this study.


Assuntos
Humanos , Masculino , Feminino , Adulto , Ombro , Acrômio , Radiografia , Dor de Ombro
4.
Biomed Chromatogr ; 34(4): e4731, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31652344

RESUMO

To assess the bioequivalence of two zolpidem hemitartrate formulations in 30 healthy volunteers. Plasma samples were obtained over a 24 h period. Plasma concentrations of zolpidem were analyzed by liquid chromatography coupled to tandem mass spectrometry with positive ion electrospray ionization using multiple reaction monitoring. Values of peak concentration (Cmax ), area under curve (AUC), half-life, elimination constant, volume of distribution and clearance showed statistically significant differences when comparing women (604.34 ng h/ml, 127.36 ng/ml, 4.4 h, 0.18 1/h, 50.56 L and 8.55 L/h, respectively) and men (276.1 ng h/ml, 70.9 ng/ml, 3.3 h, 0.26 1/h, 91.42 L and 24.34 L/h, respectively), receiving the same dose (5 mg), respectively. The geometric means with corresponding 90% confidence interval for Test/Reference percentage ratios were 99.73% (CI 93.69-106.16) for Cmax, 97.44% (90% CI = 91.85-103.37%) for area under curve of plasma concentration until the last concentration observed (AUClast ) and 98.30% (90% CI = 92.48-104.49) for the area under curve between the first sample (pre-dosage) and infinity (AUC0-inf ). Since the 90% CI for AUClast , AUC0-inf and Cmax ratios were within the 80-125% interval proposed by the US Food and Drug Administration, it was concluded that zolpidem hemitartrate formulation (5 mg orodispersible tablet) is bioequivalent to the zolpidem hemitartrate formulation (Patz SL 5 mg sublingual tablet) with regard to both the rate and the extent of absorption. A new formulation of zolpidem 2.5 mg may be useful in women for the same clinical benefits as the 5 mg formulation in men.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Zolpidem/sangue , Zolpidem/farmacocinética , Adulto , Disponibilidade Biológica , Brasil , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Comprimidos , Adulto Jovem , Zolpidem/química
5.
Rev. Inst. Adolfo Lutz ; 71(3): 507-513, jul.-set. 2012. graf
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-CTDPROD, Sec. Est. Saúde SP, SESSP-ACVSES, SESSP-IALPROD, Sec. Est. Saúde SP, SESSP-IALACERVO | ID: lil-696278

RESUMO

Neste estudo, foram feitas retrospectivamente três análises: (1) avaliação da concentração de flúor, na forma de fluoreto (F-), nas águas de abastecimento público de São José do Rio Preto (SJRP) (SP), de janeiro de 2003 a agosto de 2011, cuja análise foi efetuada por potenciometria com íon seletivo; (2) avaliação da concentração de flúor nas águas provenientes dos bebedouros das escolas municipais de Nova Aliança (NA)(SP), de agosto de 2010 a agosto de 2011, utilizando-se os princípios do heterocontrole; e (3) avaliação da variabilidade da fluoretação sob a óptica do benefício (máxima redução da cárie dentária) e do risco (ocorrência de fluorose dental). Os resultados obtidos apontaram que houve falhas na fluoretação. Em SJRPe em NA, respectivamente, apenas 53% e 23% das amostras apresentaram níveis de F- legalmente aceitos. Considerando-se a combinação de benefício máximo e risco baixo, enquadraram-se 56% das amostras de SJRP e 32% das amostras de NA. Este estudo apontou que os princípios do heter o controle foram fundamentais para efetuar a identificação de falhas na fluoretação, pois, para que se tenha máxima eficiência, o nível de flúor deve manter-se no denominado “nível ótimo” e de forma ininterrupta por longos períodos.


Assuntos
Abastecimento de Água , Cárie Dentária , Estudos Retrospectivos , Fluoretação , Flúor , Vigilância Sanitária
6.
Rev. Inst. Adolfo Lutz ; 68(3): 354-358, set.-dez. 2009. tab, graf
Artigo em Português | LILACS, Sec. Est. Saúde SP, SESSP-CTDPROD, Sec. Est. Saúde SP, SESSP-ACVSES, SESSP-IALPROD, Sec. Est. Saúde SP, SESSP-IALACERVO | ID: lil-546037

RESUMO

A água é importante fonte de ingestão de flúor e considerando-se o aumento no consumo de água mineral e da prevalência de fluorose dentária, o presente estudo teve o objetivo de avaliar a concentração de flúor na água mineral engarrafada comercializada, comparando-a aos valores declarados no rótulo da embalagem. Foram adquiridas 39 amostras água mineral de diferentes marcas disponíveis em diversos supermercados, mercearias e lanchonetes de grande circulação do município de São José do Rio Preto, em 2008. A concentração de flúor foi determinada por análise em duplicata, utilizando-se potenciômetro com eletrodo íon-seletivo. A concentração de flúor variou entre <0,05 e 0,82 mg/L, com diferenças pouco significativas entre os valores estipulados nos rótulos da maioria das marcas de água mineral e aqueles determinados na presente investigação. Os valores de flúor encontrados nas amostras analisadas mostram ser livres de risco em causar fluorose dental, porém em teor sem indicativo de ação preventiva anticárie. Os teores de flúor nas amostras de água mineral analisadas estavam em conformidade com a legislação específica vigente.


Assuntos
Eletrodos Seletivos de Íons , Fluoretos , Fluorose Dentária , Vigilância Sanitária , Água Potável
7.
Boletim do Instituto Adolfo Lutz ; (18): 49-50, 2008. tab
Artigo em Português | Sec. Est. Saúde SP, SESSP-CTDPROD, Sec. Est. Saúde SP, SESSP-ACVSES, SESSP-IALPROD, Sec. Est. Saúde SP, SESSP-IALACERVO | ID: biblio-1061243
9.
Pesqui. vet. bras ; 9(1/2): 1-7, jan.-jun. 1989. ilus
Artigo em Português | LILACS | ID: lil-114041

RESUMO

Amostras de sangue foram obtidas ao abate de 60 frangos de corte, de 43 a 56 dias de idade, de cada uma de 60 granjas sem problemas sanitários aparentes localizadas em uma regiäo de alta densidade de produçäo avícola. As granjas correspondiam a 10% do número total que existe na regiäo e estavam localizadas em um raio de 50 km. Todos os frangos tinham sido vacinados contra a doença de Marek no primeiro dia de vida. Os soros foram avaliados no teste de imunodifusäo para anticorpos para reovírus aviário (RVA), vírus da doença infecciosa da bursa (VDIB), vírus da bouba aviária (VBA), vírus herpes de perus (HVT), adenovírus aviário do grupo 1 (AVA-1) e do grupo 2 (AVA-2). Os mesmos soros foram examinados no microteste de soroneutralizaçäo em placas para anticorpos para o vírus da bronquite infecciosa (VBI) e o vírus da laringotraqueíte infecciosa (VLTI), bem como anticorpos inibidores da hemoaglutinaçäo para o vírus da doença de Newcattle (VDN). Anticorpos para RVA, detectados em 2172 (63,6%) de 3418 soros, e para AVA-1, em 2701 (78,2%) de 3456 soros, foram demonstrados em todas as 60 granjas, enquanto que, anticorpos para o VDIB, em 3086 (89,4%) de 3452 soros, foram encontrados em somente 57 destas granjas. Estes resultados indicam que os três vírus säo ubíquos em frangos de corte da regiäo estudada. Anticorpos para o VBA em 14 (0,5%) de 2935 soros, para o VDN em seis (0,2%) de 3320 soros, foram encontrados em cinco de 59 e em uma de 60 granjas, respectivamente, indicando que esses dois vírus ocorrem apenas raramente. Anticorpos para HVT, em 315 (9,0%) de 3484 soros, foram detectados em 39 de 60 granjas testadas, sugerindo resposta sorológica pobre à vacinaçäo e baixa exposiçäo de campo ao vírus da doença de Marek. Anticorpos para o VBI, em 61 (2,1%) de 2925 soros, foram encontrados em 12 de 57 granjas testadas. Porém, em apenas uma granja a percentagem de reagentes era significativa (41%); nas outras 11 granjas a percentagem de frangos com anticorpos variava de 1,7 a 16,1%. Finalmente, näo foram detectados anticorpos em 3491 soros de 60 granjas testada para AVA-2, nem em 3035 soros de 59 granjas testadas para o VLTI, indicando que esses vírus näo existem na área geográfica estudada. O significado de todos os achados é discutido


Assuntos
Anticorpos , Aviadenovirus , Bronquite , Estudos de Coortes , Herpesvirus Galináceo 2 , Laringite , Vírus da Doença de Newcastle , Reoviridae , Testes Sorológicos , Traqueíte , Bouba , Aves
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...